Pulse V4
Last updated
Last updated
First to do:
Activate the Device: --> Connect the Device via an USB data cable.
Start the Adeunis IoT Software from your computer
Set the sampling period to 1800 = Update all 1 hours / 3600 = all 2 hours
Flow calculation let it standard: 60
Type: other
Activate the Timestamp Configuration (no piucture)
Update the Time under Advanced
Before installation of the device, make sure, that you ground yourself. Otherwie the Device can shut down or even break.
Example downlink:
Warning: the value set is incorrect -> 15630916 = EE8244 so-> 00EE8244 8 digits fill up with 0
Converter: https://www.matheretter.de/rechner/zahlenkonverter Dezimal to Hexadezimal
4117000000011700EE8244 is the correct DL with your value
Downlink Port 1
___________________________________________________________________________________
The DL for moditying the registers is 0x41, to be sent to port 1
To change the initial index value of a pulse, first set it to a different pulse value and then enter the set value. The DLs are as follows, depending on your
requirements
Channel A only: 41170000000117XXXXXXXX
Channel B only : 41180000000 118X0X0XXXXX
Canal A+ Canal B: 41170000000117XXXXXXXX180000000118XXXXXXXX
00000001 = Different index values at 1 pulse, for example
XXXXXXXX = value of the index to be integrated, coded in hexadecimal
The two values (00000001 et XXXXXXXX) are different
After the downlink 0x41 is sent, the associated uplink 0x33 is immediately returned. If the update of the register(s) was successful, the device will
perform a backup and automatically begin its restart procedure. In addition, the Config bit of the status byte will be set to 1 in the next scheduled uplink
irame (periodic, alarm or keep-alive frame) if all has gone well
To help you, please find below the MRT
Warning: once this DL is used, the value read locally on the loT configurator will be equal to 0