Strega Valve
http://www.stregatechnologies.com/products/wireless-smart-valve/
Last updated
http://www.stregatechnologies.com/products/wireless-smart-valve/
Last updated
1+2 Cable through screw connection
3 Strip the cable and reinforce with solder
4 Insert the cable into the Wago terminal and check that it is seated correctly.
5 Plug the power cable into the valve head and fix it with the screw.
6 Connect the USB Cable into the USB Port and your computer
1 After the device is connected to USB, start the SV_SE_Reader programme and click on "Read Device".
2 click yes to sync the time
3 get the Device EUI
4 get the appEUI
5 get the appKEY
6 set the Join Mode to OTTA
7 check, if the device class is A (for battery mode)
All Downlinks shall be sent on Port 3
All informations about the Uplink and Downlink are in the Manuel above at the beginning.