Hawle Regelventil
Hawle Control valve
Product Datasheet
Device Profile for Tesenso IoT Cloud
Decoder/Payload Converter for Tesenso IoT Cloud
Uplink documentation
Downlink documentation
All Downlinks shall be sent on Port 3
llmmnnooooppqqrrsstt
ll=datasize in bytes = 0x09
mm= positionControlValve
nn=
motorBallValve: 0bx0=offen, 0bx1=geschlossen,
cleanDirtTrap: 0b0x=off, 0b1x=on
oooo=uplinkSendInterval in sec.
pp=inductiveSensorSlope: 0=positive steigung (4-20mA ->0-10bar), 1=negative steigung (4-20mA -> 10-0bar)
qq= uplinkConfirmation = 0: unconfirmedUplinks 1: confirmed uplinks
rr=0:dutyCycleLimits off 1: duty cycle limits on
ss=0:firstJoinDataRate with max datarate, 1: join first with min datarate
tt= +- toleranceValvePositionInPercent (0-100). Wenn Downlink Pilotventiländerung nur wenn ausserhalb Toleranz